![](/attached/image/20211018/20211018133354_90892.png)
學(xué)習(xí) | 機(jī)電安裝工程優(yōu)秀做法賞析發(fā)布日期:2019-05-22
第一部分-給排水管道安裝
![](/attached/image/20190522/20190522172228_43363.jpg)
成排管道,成排成線,支吊架牢固,管道刷漆觀感美觀。
![](/attached/image/20190522/20190522172320_14740.jpg)
消防噴淋管道間距一致,標(biāo)識(shí)清楚、成排成線。
![](/attached/image/20190522/20190522172402_46042.jpg)
噴淋支管橫平豎直,標(biāo)識(shí)清楚、支架布置間距合理。
![](/attached/image/20190522/20190522172445_99974.jpg)
成排管道,彎頭處排成一條線。
![](/attached/image/20190522/20190522172527_26724.jpg)
消火栓箱安裝,箱體外填塞密實(shí),管道安裝垂直,栓頭距地1.1米。
![](/attached/image/20190522/20190522172610_60086.jpg)
排水管道安裝坡度滿足要求,支吊架布置合理。
![](/attached/image/20190522/20190522172702_17674.jpg)
豎向排水管道,外用防護(hù)膜保護(hù),支架結(jié)實(shí)耐用,管根設(shè)置橡膠圈,界面分明。
![](/attached/image/20190522/20190522172747_60766.jpg)
成排管線共用支吊架
![](/attached/image/20190522/20190522172832_82567.jpg)
壓力排水管道閥部件布置合理,支架結(jié)實(shí)耐用。
第二部分-通風(fēng)與空調(diào)管道安裝
![](/attached/image/20190522/20190522173002_74293.jpg)
設(shè)備安裝支架結(jié)實(shí)耐用、防腐到位,減震厚實(shí)。
![](/attached/image/20190523/20190523094337_99607.jpg)
風(fēng)管穿墻,防火泥封堵到位,界面清楚。
![](/attached/image/20190523/20190523094429_25130.jpg)
排煙管道安裝,法蘭采用倒角法蘭,美觀實(shí)用,標(biāo)識(shí)清楚。
![](/attached/image/20190523/20190523094539_35020.jpg)
風(fēng)管末端固定支架設(shè)置合理。
![](/attached/image/20190523/20190523094640_93146.jpg)
風(fēng)管保溫平整厚實(shí),支吊架處采用鋼板平鋪過度,保溫釘整齊牢固。
![](/attached/image/20190523/20190523094748_73931.jpg)
空調(diào)水管道,坡度正確,支架布置合理,保溫整齊美觀。
![](/attached/image/20190523/20190523094851_22097.jpg)
空調(diào)水立管采用預(yù)制組合立管與土建結(jié)構(gòu)同步施工工藝
第三部分-電氣部分
![](/attached/image/20190523/20190523095043_20888.jpg)
強(qiáng)電管井布置合理,整齊美觀
![](/attached/image/20190523/20190523095246_16413.jpg)
電纜排布間距一致,綁扎整齊牢固。
![](/attached/image/20190523/20190523095344_48137.jpg)
標(biāo)識(shí)牌清楚明確,排列整齊。
![](/attached/image/20190523/20190523095515_52532.jpg)
![](/attached/image/20190523/20190523095516_44594.jpg)
橋架安裝牢固,跨接滿足要求。
![](/attached/image/20190523/20190523095643_20140.jpg)
![](/attached/image/20190523/20190523095644_39121.jpg)
等電位焊接牢固,彎曲半徑美觀,標(biāo)識(shí)醒目。
![](/attached/image/20190523/20190523095808_66698.jpg)
![](/attached/image/20190523/20190523095809_49771.jpg)
防火封堵平整密實(shí),界面清晰。
![](/attached/image/20190523/20190523095922_66589.jpg)
線槽等成排成線,美觀大方。
![](/attached/image/20190523/20190523100040_46489.jpg)
成排橋架,布置合理,共用支吊架采用C型鋼+槽鋼整體支架體系
![](/attached/image/20190523/20190523100139_98663.jpg)
線槽支架布置合理,接地扁鋼標(biāo)識(shí)清楚。
![](/attached/image/20190523/20190523100246_75808.jpg)
線槽穿越墻體防火封堵清楚
第四部分-設(shè)備支吊架
![](/attached/image/20190523/20190523100411_71287.jpg)
![](/attached/image/20190523/20190523100411_80340.jpg)
支吊架在梁上生根,焊接轉(zhuǎn)角處采用鋼板補(bǔ)強(qiáng)。
![](/attached/image/20190523/20190523100555_48394.jpg)
![](/attached/image/20190523/20190523100556_70105.jpg)
![](/attached/image/20190523/20190523100556_87622.jpg)
![](/attached/image/20190523/20190523100556_31456.jpg)
槽鋼支架選型正確,加工45度角切割煨彎焊接,吊桿布置合理,端頭雙螺栓固定,管卡型鋼機(jī)械開孔。
![](/attached/image/20190523/20190523100716_96075.jpg)
電氣橋架,專用固定支架,焊接牢固,防腐滿足要求。
![](/attached/image/20190523/20190523100826_89461.jpg)
![](/attached/image/20190523/20190523100827_98129.jpg)
![](/attached/image/20190523/20190523100827_35108.jpg)
成品支吊架施工,結(jié)實(shí)耐用美觀,支架改造重復(fù)利用率高。
![](/attached/image/20190523/20190523100936_58573.jpg)
支架接地,安全有效。
第五部分-裝配式機(jī)房
![](/attached/image/20190523/20190523101113_36983.jpg)
![](/attached/image/20190523/20190523101113_82524.jpg)
設(shè)備支架結(jié)實(shí)牢固
![](/attached/image/20190523/20190523101254_72161.jpg)
![](/attached/image/20190523/20190523101255_78593.jpg)
![](/attached/image/20190523/20190523101255_80314.jpg)
設(shè)備布置成排成線,加工廠預(yù)制成型,模塊化吊裝施工。
![](/attached/image/20190523/20190523101431_24472.jpg)
排氣孔、冷凝排水孔設(shè)置合理
![](/attached/image/20190523/20190523101529_95821.jpg)
水泵減震、限位裝置布置合理,科學(xué)實(shí)用。
![](/attached/image/20190523/20190523101634_66820.jpg)
閥部件安裝牢固,螺絲朝向正確美觀。
![](/attached/image/20190523/20190523101723_27980.jpg)
水泵集水槽設(shè)置巧妙,排水合理。
![](/attached/image/20190523/20190523101824_43814.jpg)
電機(jī)外殼重復(fù)接地,有效美觀。
![](/attached/image/20190523/20190523101957_50112.jpg)
![](/attached/image/20190523/20190523101958_79648.jpg)
支管與干管連接處采用順?biāo)ā?/span>
![](/attached/image/20190523/20190523102058_46936.jpg)
水泵進(jìn)出口大小頭設(shè)置合理
![](/attached/image/20190523/20190523102159_27914.jpg)
閥門螺栓朝向安裝正確。
![](/attached/image/20190523/20190523102253_66392.jpg)
立管減震支架
![](/attached/image/20190523/20190523102343_34419.jpg)
地面管根橡膠圈處理
![](/attached/image/20190523/20190523102440_46027.jpg)